Home > VRF air conditioner
1.Description of Commercial air conditioner outdoor unit V5 X SERIES VRF AC and DC
1)Wide Application Range
A.Wide Capacity Range
The V5 X series has an extensive range of capacities, from 8HP to 88HP, meeting all customer requirements from small to large buildings.
B.Wide Range of Indoor Units
We provides 12 types and more than 100 models of VRF indoor units to meet varied customer requirements in a wide range of locations including shopping malls, hospitals, office buildings, hotels and airports.
C.Wide Operation Range
V5X Series operates stably under extreme conditions, ranging from minus 20°C to 48°C.
D.Long Piping Capability
Piping length | Capability |
Total piping length | 1000m |
Longest length - actual (equivalent) | 175m (200m) |
Longest length after first branch | 90m* |
Largest height difference between indoor and outdoor units - ODU up (down) |
90m (110m) |
Largest height difference between indoor units |
30m |
2)High Reliability
A.Duty Cycling
Duty cycling equalizes the running time of the outdoor units in a multiple-unit system and of the compressors in each unit, significantly extending compressor lifespan.
B.Backup
In a multi-unit system, if one module fails, the other modules provide backup so that the system can continue operating.
C.Precise Oil Control Technology
Five stages of oil control technology ensure all outdoor compressor oil is always kept at a safe level, eliminating any compressor oil shortage problems.
The 1st stage: Compressor internal oil separation.
The 2nd stage:High-efficiency centrifugal oil separator (with separation efficiency of up to 99%) ensures that oil is
separated from the discharge gas and returned to the compressors in a timely fashion.
The 3rd stage:Oil balance pipes between compressors ensure even oil distribution to keep compressors running normally.
The 4th stage:Oil balance pipes among modules ensure even oil distribution among modules.
The 5th stage:Auto oil return program monitors the running time and system status to ensure reliable oil return.
2.Specification of Commercial air conditioner outdoor unit V5 X SERIES VRF AC and DC
380-415V 50(60)Hz / 220V 60Hz
Note:Indoor temperature 27°C (80.6°F) DB, 19°C (66.2°F) WB; outdoor temperature 35°C (95.0°F) DB; equivalent refrigerant piping length 7.5m (24.6ft.) with zero level difference.
Indoor temperature 20°C (68.0°F) DB; outdoor temperature 7°C (44.6°F) DB, 6°C (42.8°F) WB; equivalent refrigerant piping length 7.5m (24.6ft.) with zero level difference.
Diameters given are those of the unit's stop valve.
Sound pressure level is measured at a position 1m (3.28ft) in front of the unit and 1.3m (4.3ft) above the floor in a semi-anechoic chamber.
3.Relate products
Contact: Mr. Lee
Phone: +8613702622945
Tel: 0757-63906939
Email: ford.lee@orienthvac.com
Add: NO.51 Fengxiang Road, Daliang town,Shunde ,Foshan,GuangDong ,P.R.CHINA and (HongKong Office)FLAT/RM B 8/F CHONG MING BUILDING 72 CHEUNG SHA WAN RD KL,Hongkong